Princeton Applied Research-VersaSTAT (Model: 4 )

3
448
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

Overview

The VersaSTAT 4 builds upon the already impressive new design of the VersaSTAT 3 giving you even more improved speed, versatility, and precision required for a range of electrochemical applications.

The increased maximum current of 1A standard as well as optional current boosters up to 20A, positions the VersaSTAT 4 to take you from the early stages of battery and fuel cell development to the charge/discharge experiments on the final product and the challenges that lie ahead for the next generation of batteries.

The improved low current performance with fA resolution and pA accuracy addresses current sensitive applications such as sensors, corrosion, inhibitors, and combined with the optional FRA, coating technologies.  The additional analog filtering makes the VersaSTAT 4 an even better choice for corrosion applications while the additional bandwidth filtering adds extra stability for capacitive cells.  The VersaSTAT 4, with its additional capabilities, makes an exciting addition to our VersaSTAT family making them even more of an exceptional value for all of your application needs.

  • Improved low current performance with fA resolution and pA accuracy
  • Maximum current up to 1A with additional bosster options ranging from 2A-20A
  • 2µs time base for faster data acquisition and faster scan rates
  • Additional analog filter selections on current and voltage channels for superior signal/noise measurements
  • An internal frequency response analyzer option that provides impedance analysis over the frequency range 10µHz to MHz
  • Easy-to-use VersaStudio software included

Specifications

Data Acquisition

Data Acquisition

3 x 16 bit 500k samples per second ADCs synchronized voltage/current/auxiliary

Time Base Resolution (min)

2µs (500k samples/second)

Automatic Noise Filters

Enabled/disabled

Power Amplifier

Voltage Compliance

±12V

Current Compliance

±1A (standard)

±2A (with 2A option)

Potentiostat Bandwidth

1 MHz

Stability Settings

six settings; high stability, 1Mhz-100Hz

Slew Rate

>8V per µs typical (no load)

Rise Time (-1.0V to +1.0V)

<350 ns (no load)

Voltage Control (potentiostat mode)

Applied Voltage Range

±10V

Applied Voltage Resolution

for ±10mV signal = 300nV

for ±100mV signal = 3µV

for ±1V signal = 30µV

for ±10V signal = 300µV

Applied Voltage Accuracy

±0.2% of value ±2mV

Maximum Scan Rate

5000 Vs-1 (10 mV step)

Maximum Scan Range

±10V / 300µV

Current Control (galvanostat mode)

Applied Current Range

±full scale (depends on range selected)

±1A (standard), ±2A (with option)

Applied Current Resolution

±1/32,000 x full scale

Applied Current Accuracy

±0.2% of reading, ±0.2% of range

±200pA

Max. Current Range/Resolution

±1A / 60µA

Min. Current Range/Resolution

±4nA / 120 fA

Electrometer

Max. Input Range

±10V

Bandwidth

≥10MHz (3dB)

Input Impedance

≥1012 Ω in parallel with ≤5pF (typical)

Leakage Current

≤5pA at less than 25°C

CMRR

60 dB at 100kHz (typical)

Voltage Measurement

Voltage Range

±10V

Minimum Resolution

6µV

Voltage Accuracy

±0.2% of reading, ±2mV

Current Measurement

Current Ranges

Auto-ranging (10 ranges)

1A to 4nA (8 ranges)

2A to 4nA (with option)

Current Resolution

120 fA (4nA range)

Current Accuracy (DC)

20nA to 2A: ±0.2% of reading, ±0.2% of range

4nA: <0.5% ±20pA

Bandwidth

1MHz (signal ≥2mA range typical)

Bandwidth limit filter

Yes, five total

Impedance (EIS) Option

Mode

Potentiostat/Galvanostatic

Frequency Ranges

10µHz to 1MHz

Minimum AC Voltage Amplitude

0.1mV RMS

Sweep

Linear or Logarithmic

iR Compensation

Positive Feedback

Yes

Dynamic iR

Yes

Interfaces (included as Standard)

Digital inputs/outputs

5 TTL logic outputs, 2 TTL logic inputs

Auxiliary Voltage Input

Measurement synchronized to V and I

±10V range, input impedance 10kΩ

Filter: off, 1kHz, 200kHz

BNC connector

DAC Voltage Output (Standard)

±10V range, output impedance 1kΩ

BNC connector (for stirrers, rotating disk

electrode etc.)

PC / Software

Communications Interface

Universal Serial Bus (USB)

Operating System

Windows 7 (64-bit & 32-bit)

Windows XP / Vista

PC Specification (minimum)

Pentium 4 (1GHz) / 1GB memory

High Data rates may require additional

memory

Software

VersaStudio

General

Power

250VA Max.

Voltage range 90Vac to 250Vac, 50-60Hz

Dimensions

16¼” x 15¼” x 3½”   421 x 387 x 89mm

Weight

10lbs, 4.5kgs

Operating Temperature Range

10°C to 50°C

Humidity

Maximum 80% non-condensing

Temperature (specified)

25°C

Dummy Cell

Internal (DC only)

CE Approved

Yes

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | Princeton Applied Research-VersaSTAT (Model: 4 ).