PSU-1AC/ASi-4A
datasheet.
|
Product characteristics |
||||||||
|
Power supply |
||||||||
|
AS-i power supply 115/230 V AC |
||||||||
|
Integrated data decoupling |
||||||||
|
Application |
||||||||
|
Application |
AS-i system voltage for masters, sensors, actuators and modules |
|||||||
|
Electrical data |
||||||||
|
Input voltage range [V] |
100…120 AC / 200…240 AC; ± 10 %; automatic range selection |
|||||||
|
Nominal voltage [V] |
115 / 230 AC |
|||||||
|
Frequency range [Hz] |
47…64 |
|||||||
|
Nominal frequency [Hz] |
50 / 60 |
|||||||
|
Output voltage (AS-i) [V] |
30.5 DC |
|||||||
|
Output power [W] |
122 |
|||||||
|
Output power peak [W] |
134; briefly to load bus capacities after power on |
|||||||
|
Power factor |
0.56 (120 V AC; 60 Hz) / 0.47 (230 V AC; 50 Hz) |
|||||||
|
Power reserve [%] |
10 |
|||||||
|
Output current (AS-i) [A] |
4 |
|||||||
|
Residual ripple [mVpp] |
< 50 |
|||||||
|
Switch-on peak current [A] |
3 (120 V AC; 60 Hz) / 3 (230 V AC; 50 Hz) |
|||||||
|
Inrush current limitation |
yes |
|||||||
|
Efficiency [%] |
88 (120 V AC; 60 Hz) / 89.3 (230 V AC; 50 Hz) |
|||||||
|
Short-circuit proof |
yes |
|||||||
|
Overload protection |
yes |
|||||||
|
Overload performance |
constant output current |
|||||||
|
Overvoltage protection [V] |
< 36 |
|||||||
|
Excess temperature protection |
yes |
|||||||
|
External input protection |
≤ B-10 A / ≤ C-6 A |
|||||||
|
Power-on delay time [ms] |
≤ 900 |
|||||||
|
Derating [W/K] |
3 (60…70 °C) |
|||||||
|
Mains buffering time [ms] |
70 (120 V AC; 60 Hz) / 70 (230 V AC; 50 Hz) |
|||||||
|
Protection class |
I |
|||||||
|
Input current [A] |
2.05 (120 V AC; 60 Hz) / 1.23 (230 V AC; 50 Hz) |
|||||||
|
Power loss [W] |
16.6 (120 V AC; 60 Hz) / 14.6 (230 V AC; 50 Hz) |
|||||||
|
Back feeding protection [V] |
≤ 35 DC |
|||||||
|
Block diagram |
||||||||
|
Output curve |
||||||||
|
Characteristic curve for degree of efficiency / power loss |
||||||||
|
Characteristic curve for derating |
||||||||
|
Characteristic curve for mains buffering time |
||||||||
|
Outputs |
||||||||
|
Parallel connection of outputs |
no |
|||||||
|
Series connection of outputs |
no |
|||||||
|
Environment |
||||||||
|
Ambient temperature [°C] |
-25…70, observe the free space for convection (see operating instructions) |
|||||||
|
Storage temperature [°C] |
-40…85 |
|||||||
|
Max. relative air humidity [%] |
95, (IEC 60068-2-30) |
|||||||
|
Protection |
IP 20 |
|||||||
|
Degree of soiling |
2; (IEC 62103) conductive soiling not permitted |
|||||||
|
Tests / approvals |
||||||||
|
EMC |
|
|||||||
|
UL |
UL 508 (Industrial Control Equipment) |
|||||||
|
Shock resistance |
|
|||||||
|
Vibration resistance |
|
|||||||
|
MTBF [h] |
789000 |
|||||||
|
AS-i classification |
||||||||
|
AS-i certificate |
98601 |
|||||||
|
Mechanical data |
||||||||
|
Housing materials |
steel sheet |
|||||||
|
Installation |
rail TH35 (to EN 60715) |
|||||||
|
Weight [kg] |
0.62 |
|||||||
|
Displays / operating elements |
||||||||
|
Function display LED |
green (indication AS-i voltage) |
|||||||
|
Electrical connection |
||||||||
|
Connection |
screw terminals |
|||||||
|
Wiring
|
||||||||