DRUCK-Loop Calibrator ( Model: UPS-III)

0
332
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

 The UPS III is a high accuracy loop calibrator. Its size makes it rugged and extremely compact. Measuring 3” x 5” and weighing just 9.7 ounces, it fits comfortably in a shirt pocket.

It is an essential tool for loop testing, instrument maintenance and valve set-up, with an easy to read display and simple to use time saving features.

Features

  • Measure or Source 0 to 24 mA
  • Accuracy 0.01% of reading
  • Dual mA and % readout, linear or flow
  • Step, Span Check, Valve Check, Ramp
  • 6 VDC measurement and continuity
  • HART® compatible

 Applications

Graphic Display
The graphic display with menu-driven interface is easier to use than traditional knobs, switches, multi-function keys and dual key sequences.

Measure or Source 0 to 24 mA
An internal 24 V loop supply is available in both measure and source modes, essential during plant shutdowns.

Accuracy 0.01% of Reading
This includes 12 month stability and temperature effects. The UPS III can maintain a 4:1 calibration ratio with the latest instrumentation and is typically 20 to 80 times more accurate than a Digital Multi-Meter (DMM).

Simultaneous % Readout
Displays mA and the percentage value of 4 to 20 mA or 0 to 20 mA. The UPS III also converts mA readings to % flow. This is not possible with many loop calibrators.

Step, Span Check and Value Check
Step quickly through linearity tests and zero/span adjustments. In valve mode, seating can be checked and the positioner set.

Auto Step and Ramp
Outputs have adjustable rates (1 to 599 s) for single-handed loop testing, valve set-up and slew rate checks.

“Fast Set” Output
Allows values to be set to within 0.001 mA using the arrow keys. Holding a key quickly ramps the output to the next value. The system is ideal for alarm trip tests.

60 VDC Measurement
For loop diagnostics and maintenance of voltage output instruments.

Continuity and Switch Test Facility
This reduces DMM dependence when fault finding, checking loop integrity and testing switches.

Hart Compatible
Internal 235 O loop resistor (menu selectable)

EMC compliance to EN 61326-1
Complies with heavy industry standard. Most loop calibrators are only suitable for light industrial use. 
 

 Specifications

Performance

UPS III - Loop Calibrator Chart

Electrical

Power Supply 4 x 1.5 V AA-size alkaline batteries (standard) or universal power supply (see option B)
Battery Life 75 hours in read mode, 18 hours at 12 mA
Auto Power Down 30 minutes after last key press
Low Battery Warning Battery symbol displayed
Open Loop Flashes “open loop”
Loop Resistance High Flashes “check loop O”
Out of Range Displays (over)
Hart Resistor 235 O menu selectable loop resistor

UPS III - Loop Calibrator Description

Environmental

Calibration Reference 72°F (22°C) ±2°F(±3.6°C)/RH 45% ±15%
Operating Temperature 14°F to 122°F (-10°C to 50°C)
Relative Humidity 0% to 90% non-condensing
Conformity EN 61010, /EN 61326-1:1997 + A1:1998, CE marked

Physical

Housing Material High impact ABS
Dimensions (w x h x d) 3 in x 5 in x 1 in (77 mm x 129 mm x 24 mm)
Weight 9.7 oz (275 g) including batteries
Display Graphic LCD, 1.2 in x 2.1 in (31 mm x 54 mm)
Electrical Terminals Gold plated, 4 mm sockets

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | DRUCK-Loop Calibrator ( Model: UPS-III).