Solartron Analytical -Eight Channel Potentiostat/Galvanostat (Model:1470E )

0
417
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

Overview

The Solartron CellTest System is a multi-channel test system designed for the complete DC and impedance characterization of a wide range of energy storage devices such as batteries, fuel cells and super-capacitors. The speed, range and resolution of the CellTest system also make it suited to other research applications including the analysis of sensors, coatings, corrosion and general
electrochemical applications.
The CellTest system consists of one or more 1470E multi-channel potentiostats and multiple 145x series frequency response analyzers (FRAs) connected to a computer providing simultaneous DC and impedance tests on multiple cells. Each 1470E unit provides eight fully independent potentiostats, allowing up to eight separate cells to be tested simultaneously. Each channel is
completely independent allowing the same or quite different experiments to be run on each cell.

The CellTest system provides a wide range of experimental techniques, including charge / discharge, potentiostatic, potentiodynamic, galvanostatic, galvanodynamic, fast cyclic voltammetry, open circuit, fast pulse and step techniques, ohmic-drop analysis and impedance.

Simultaneous impedance tests can be run on multiple cells by connecting Solartron 145x series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455 FRA provides high performance impedance measurements over the frequency range 10μHz to 1MHz, while the 1451 FRA operates from 10μHz to 100kHz. Temperature controlled ovens and furnaces can be added to the system and automatically controlled from the PC over a serial communications link, providing the facility to test cells at different temperatures (for example for testing solid oxide fuel cells at up to 1000oC).

Ethernet control
The 1470E and 145x FRA units are Ethernet controlled providing either local or remote control of the instrumentation from a PC connected anywhere on the same Ethernet network. This allows experiments to be set-up and run from a quiet office environment while the test equipment and cells are located quite separately in another room or building. The Solartron CellTest system is the most advanced multi-channel battery, fuel cell, supercapacitor test system available, giving the ultimate in DC and impedance test performance.

Specifications

PC Communication Ethernet 10BaseT or IEEE488 (GPIB). Refer to back page for details
Number of Channels 8 independent floating channels per unit
Counter Electrode (CE)
Maximum voltage / current +10V / -3V, ±4A
Maximum power per channel 40W
Selectable bandwidth 10, 100, 1k, 10k, 100k, 1MHz
Voltage measurement input (RE1, RE2)
Connections Driven shields for wide bandwidth
Maximum voltage +10V / -3V
Voltage ranges Auto-range or manaully selected 10v, 1V, 100mV
Accuracy ±0.1% of range
Voltage resolution 3µV
ADC 16 bit 10,000 samples / sec
Input impedance >10Gohm
Current Measurement input (WE)
Maximum current per channel +4/-4A
Current ranges Auto-range or manually selected 5A 500mA, 50mA, 5mA, 500µA, 50µA
Accuracy ±0.1% of range
Current resolution 1.5nA
ADC 16 bit 10,000 samples / sec
Experiment
Maximum steps/experiment 100
Step types:
voltage, current constant, ramp, pulse (includes high speed GSM), cyclic voltammetry
power, resistance constant level (discharge only)
other rest (open circuit), loop
impedance requires one or more frequency response analyzers
Step termination limits voltage, current, power, resistance and charge. temperature (requires option 14703A)
Time to switch test type 100µsec
Minimum sample rate 1 sample / 100 seconds
Maximum sample rate 10,000 samples / second
Measurement modes Fixed sample rate or measure on change
Shutdown safety limits voltage, current temperature (requires option 14703A)
Temperature control Eurtherm 2000 Series controllers
Temperature Range
Operating 5º to 40ºc (41º to 104ºF)
Specified accuracy 10º to 30ºC
Storage -25º to 70ºC (-13º to 158ºF)
General
Dimensions (w x h x d) 450 x 286 x 496mm
(17.7 x 11.3 x 19.5in)
Weight 18kg (40lb)
Safety complies with BS EN 61010
EMC complies with BS EN 61326
Line Voltage 85V to 264V 47-63Hz
Power 1000VA Maximum

Cell connection cable set for 1470E
8 channel cable set included (1 metre length)

14703A Option Specification

Temperature measurement
Temperature inputs 8 (one per main channel)
Thermocouple types E, J, K, T
Temperature accuracy ±1ºC (plus thermocouple errors)

Min (ºC)

Max (ºC)

Resolution (ºC)

Type E

-200

1000

0.0625

Type J

-210

1200

0.0625

Type K

-200

1372

0.0625

Type T

-200

400

0.0625

The 14703A option provides:

  • Temperature safety limits
  • Temperature measurement with plots vs time
  • Temperature step termination limits

Thermocouple Interface Unit included – for cold junction compensation (with 1 metre connection cable to 1470).

Thermocouples must be chosen to suit temperature range requirements and are therefore not supplied with this option.

Control Outputs
Control outputs 24 (three per main channel)
Switch type Opto-isolated solid-state switches (similar to relays)
Connections 2 per switch
Maximum voltage 50V
Maximum current 100mA

Control outputs can be automatically switched on/off at each step in the experiment to control external devices (relays, lamps. heaters, gas values, power boosters etc.).

Supplied with a D-type connector for customers to make up their own connection leads.

14702A Option Specification*
Auxiliary Voltage Channels (similar to RE1, RE2)

Connections Driven shields for wide bandwidth
Maximum voltage +10V / -3V
Voltage ranges Auto-range 10V, 1V, 100mV
Accuracy ±0.1% of range
Voltage resolution 3µV
ADC 16 bit 10,000 samples / sec
Input impedance >10Gohm
DC measurements synchronized to assigned main channel

Cell connection cable set for 14702A
8 channel cable set inclused (1metre length)

* IMPORTANT NOTE: Option 14702A requires 14703A to be fitted.

145x Frequency Response Analyzer Specification

Chassis 1400A – 8 slot chassis
PC communications Ethernet 10 / 100BaseT
Number of FRAs per chassis Up to 8 independent floating FRAs
Measurement connections differential voltage generator and analyzer connections to 1470E via supplied cable
Measurement speed >30 impedance results / second or 1 measurement per waveform cycle, whichever is slower
Generator
Maximum DAC sample rate 40MHz (40x over-sampled)
Frequency range
1455
1451
10µHz to 1MHz
10µHz to 100kHz
Frequency resolution 1 in 65,000,000
Frequency error ±100ppm
Generator amplitude 50µV to 3Vrms
Output Short circuit protected
Output impedance 50 ohms
Output waveforms Single sine, multi-sine
Single sine
(PC frequency selection)
Linear / logarithmic sweep
Multi-sine
No. of frequencies
Frequency

Frequency selection

up to 3 decades per measurement, >3 decades by sequential measurements
up to 50 (user selectable), or all

Analyzers
Maximum ADC sample rate 40MHz (40x over-sampled)
Frequency range
1455
1451
10µHz to 1MHz
10µHz to 100kHz
Accuracy ±0.1%, ±0.1º (input X / Y)
Analyzer modes Single-sine or FFT / harmonic analysis (all modes available throughout the entire frequency range)
Voltage ranges Auto-range or manually selected 3V, 300mV, 30mV (rms levels)
Maximum voltage resolution 1µV
Phase resolution 0.01º
Integration time 10msec to 105 seconds
1 cycle to 106 cycles
Auto-integration long, short or off
DC bias rejection Automatic
Anti-alias filters (all channels) cut-off > 1MHz
Digital filtering automatic
Auxiliary Voltage Analyzers – for the impedance analysis of cell anode / cathode
(Requires 14702A/14703A options fitted to 1470E)
Connections Differential voltage (via 1470E)
Number of auxiliary inputs

Resource & Download